Please refer to the below table:
Model |
GSD-808HP |
|
PoE Budget |
130 Watts |
|
PoE Ability |
Number of Class 1 PD, <3.8W |
8 |
Number of Class 2 PD, <6.5W |
8 |
|
Number of Class 3 PD, <12.9W |
8 |
|
Number of Class 4 PD, 25W |
5 |
|
Input Power |
100~240V AC / 50-60Hz |
Please refer to following table for detail about difference between POE-E101 and
POE-E201.
Model |
POE-E201 |
POE-E101 |
Data Rate |
10/100/1000Mbps |
10/100Mbps |
Weight |
197g |
215g |
Power Requirement |
IEEE 802.3at compliant with voltage within 52V-56V DC |
IEEE 802.3af compliant with voltage within 44V-56V DC |
Power Consumption |
3.2Watts (maximum) |
1.9Watts (maximum) |
Standard Compliance |
IEEE 802.3ab 1000Base-T Gigabit Ethernet |
- |
IEEE 802.3at High Power over Ethernet |
- |
Model Name |
POE-151S& POE-152S |
POE-161S |
Output Voltage/Current |
Adjust by DIP switch: |
Adjust by DIP switch: DIP switch at 5V: 5VDC,4.5A max DIP switch at 12V: 12VDC, 2A max |
Model Name |
POE-151 & POE-152 |
POE-161 |
PoE Standard |
IEEE 802.3af Power over Ethernet |
IEEE 802.3at Power over Ethernet pre-standard |
Output Watts |
15.4 Watts maximum |
30 Watts maximum |
Due to a different hardware design and PoE PSE port operation mode, we don’t suggest doing this kind of connection. Otherwise, it may damage the equipment.
Please use straight cable connects to your PoE device between PoE injector Hub and don’t use crossover RJ45 cable on your PoE network deployment.
Press the RESET button at front panel about 10 seconds and then release. The POE-1200P2 / POE-2400P4 will back to the factory default (Username / password: admin, IP: 192.168.0.100).