The following devices are selected for making point to point calls:
Equipment 1 : HDP-1100PT (IP 192.168.1.76)
Equipment 2 : VTS-700P (IP 192.168.1.71)
Equipment 3 : ICF-1800 (IP 192.168.1.220)
The network segment must be the same.
Application 1
HDP-1100PT is dialing to VTS-700P
HDP-1100PT (192.168.1.20)
Path: Service à SIP
1. Setting up the Dial Button : 123@192.168.1.71:5060
2. Save and reboot.
Note : 123 is free to set up to ensure the IP address of VTS-700P and port 5060.
After it is finished,you can dial now.
Application 2
VTS-700P is dialing to HDP-1100PT
VTS-700P (IP 192.168.1.71)
Step 1
Path: Intercom à Camera
1.Set up the URL : rtsp://admin:admin@192.168.1.76/cam1/h264
2.Save the configuration.
HDP-1100PT (192.168.1.76)
Step 2
1.Setting the ERL:/cam1/h264
2.Save and reboot the device.
Now you can press the camara button on VTS-700P to view the HDP-1100PT.
Application 3
ICF-1800 is dialing to HDP-1100PT
HDP-1100PT (192.168.1.76),ICF-1800 (IP 192.168.1.220)
1.Setting up the Dial Button : 123@192.168.1.220:5060
2.Save and reboot.
Note: 123 is free to set up to ensure the IP address of ICF-1800 and port 5060.
After it is finished, you can dial now.
The ICF-1800 will show the IP of the person who is dialing.
Application 4
HDP-1100PT is dialing to ICF-1800
Dial number: 192*168*1*76 = Calling to 192.168.1.76